Ball mill Parameter setting / run time setting - DELIXI Converter U code
Question: Could you give me som brief instruction on how to set a program that runs for 10 minutes in one single direction, and an other that runs in one direction for 10 minutes, stops and rotates for 10 minutes in the other direction then starts over? Answer: 1, set program that runs for 10 minutes in one single direction: Set total time 10mins: press mode key enter U3224, change it to 0010. Make sure U3004 and U3006 are both 10 mins (0010); make sure U3035 and U3036 are same(either H010 or H110). Then start run. 2, set program that runs in one direction for 10 minutes, stops and rotates for 10 minutes in the other direction then starts over: Set total time 20 minutes times cycle number, e.g. 100 minutes: press model key enter U3224, change it to 0100. Set U3004 to 0010, U3006 to 0010; make sure U3035 and U3036 are different (if U3035 is H010, make U3036 is H110). If need pause time, enter U3217 change it to any time (E.g. 0060 means 60 seconds), if no need pause time, change U3127 to 0. Note: total run time = (forward rotate time + pause time + reversal rotate time + pause time) * cycle number. Producer: James Song Contact: [email protected]