How to Take Drain Level Using Auto Level | Practical Site Guide In this practical civil engineering tutorial, learn how to take accurate drain bed levels using an Auto Level. This video will guide you step-by-step through the entire process, including how to place the staff on the TBM, perform backsighting, and read bed level readings with precision. You’ll also see how to calculate Reduced Levels (RL) and Foresight (FS) using the formula TBM + BS = Hi and Hi - RL = FS. What You Will Learn in This Video: How to position the staff on TBM for accurate backsight readings. Step-by-step method for taking bed level readings with an Auto Level. How to calculate RL for precise drain leveling. Formula used: TBM + BS = HI, HI - RL = FS. Why Watch This Video: Learn fieldwork essentials for accurate drain leveling. Apply the TBM + BS = Hi, Hi - RL = FS formula correctly for error-free measurements. Improve your practical surveying skills and become more efficient on-site. Don't forget to like, share, and subscribe for more in-depth civil engineering tutorials! --- Hashtags: #drain #rl #autolevel #surveying #tbm #autolevelsurvey #drainlevel #civilengineering #constructionequipment #fieldwork #construção