WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD?
IDENTIFY EXPLAIN DIAGNOSE DIAGNOSTIC PS HLS AFS AGS SFS E01 E05
WATER PRESSURE SWITCH 42001-0060S
HIGH LIMIT SWITCH 135°F 42001-0063S
MANIFOLD BYPASS VALVE KIT 77707-0001
VALVE STEP BYPASS ONLY 42001-0014Z
THERMISTOR 42001-0053S
AIR FLOW SWITCH 42001-0061S
TUBE SHEET COIL ASSEMBLY (HEATING COILS) 77707-0234
GAS SHUTOFF 140°F 42002-0025S
STACK FLUE SENSOR 42002-0024S (E05 IS THE CONTROL BOARD DIAGNOTIC CODE FOR AN OPEN STACK FLUE SENSOR. CHECK FOR CORRODED CONNECTORS, BROKEN WIRES TO THE STACK FLUE SENSOR OR REPLACE THE STACK FLUE SENSOR COMPLETELY IF YOU GET E05 ON YOUR DISPLAY)