Installing tension control (TC) bolts? There's a method for that.
The Twist-Off Tension Control Bolt method is one of the installation methods outlined by the RCSC. Performing a pre-installation verification (PIV) ensures each bolt reaches the minimum required pretension prior to working on the structure.
In this video, we demonstrate this method using a 3/4" TC bolt, a shear wrench and a bolt tension measure device to verify installation meets specifications.
• RCSC specifications → https://www.gwyinc.com/resources/rcsc-specifications/.
Explore tools used for this PIV:
• Shear Wrenches → https://www.gwyinc.com/tc-shear-wrenches/
• Bolt Tension Calibrators → https://www.gwyinc.com/bolt-tension-calibrator/
Need help with your pre-installation verification? Contact us for training, tools, and expertise.