Camera Calibration Pro 24, 36, 48
17000 - Fusion Maker, Edge, and Pro - Camera Calibration Camera Calibration (Fusion Pro 24 & 36) The camera calibration ensures that the IRIS camera system offers optimum accuracy when displaying artwork on material and when completing print-to-cut applications. The camera calibration should not be completed regularly. Instead, the camera calibration should only be completed if any of the following behaviors are observed: Camera feed appears completely black. Camera feed displays a black semi-circle overlay. Camera feed appears rotated 90-180 degrees. Camera feed of the art placement location does not coincide with the location of the engraving and or cuts on material. Additionally, a camera calibration may be needed if any of the following components have been replaced or certain engraver settings have been changed: Overhead or carriage camera Laser Focus Home position Many location-based camera errors are caused by focus or positioning issues. Before completing a camera calibration to resolve a location-based camera issue, ensure that the engraver is properly focused and the accuracy of the XY home position. All focus calibrations must be completed before a camera calibration to ensure accurate results