H5 = IPM sync issue or overcurrent detected.
Before replacing a board or compressor, check the basics.
Quick Checks:
- Verify airflow: clean filters, coils, blower wheel
- Clear outdoor coil and confirm proper clearance
- Confirm service valves open and system properly evacuated
- Check standing pressure vs. outdoor temp (PT chart)
- Inspect wiring and board installation - all screws installed and tight
- Check compressor resistance (U-V, U-W, V-W should be equal)
- Test windings to ground (should be infinite resistance)
Restart & Observe:
- No amp draw on a leg = main board failure
- Amp draw on all legs but no start = seized compressor
- Runs but trips H5 = check charge, restrictions, airflow, piping, or thermistors
- Always identify the root cause before compressor replacement.
Hope this helps you troubleshoot when you're out in the field. With GREE, we’re by your side.
Download
0 formats
No download links available.